TitleProduct

Tube In Tube Condenser

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2021-03-20 11:31

  • Browse the number:

    199

Send an inquiries

Company Profile

Guangzhou United A/C & R Co., Ltd

By certification [File Integrity]

Contact:gzlianhe(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website:http://www.heatexchangermaker.com/ http://gzlianhe.hfruijia.com/

Product Details


Product Introduction

The tube in tube condenser has two structures: single-pass and multi-pass. Each time the fluid flows through a set of heat exchange tubes, it is called a tube pass. A four-pass condenser means that the fluid flows through four sets of Shell and Tube Heat Exchanger tubes.

Product Details

A four-pipe Shell and tube Condenser is equipped with four or two baffles in the tube box at one or both ends of the condenser, so that the fluid only flows through a set of heat exchange tubes in the tube in tube condenser at a time, and finally flows out of the condenser from the outlet.



Product parameters

Heat and cold reclaimer

model

Norminal heat exchange(KW)

inlet & outlet

(inch)

Refrigerant inlet

(inch)

Refrigerant outlet

(inch)

Length A

(mm)

Width B

(mm)

Height C

(mm)

weight

(kg)

R22

R134a

R407C

UHR080A

343

275

309

3"

2-1/8"

2-1/8"

2535

470

420

255

UHR085A

365

292

328

4"

2-1/8"

2-1/8"

2623

507

257

280


Four return condensers are mainly composed of shell, tube bundle, tube plate and end cover. The shell is mostly round, with parallel tube bundles inside, and both ends of the tube bundle are fixed on the tube plate. Two fluids that exchange heat in the condenser, one flows in the tube and its stroke is called the tube side; the other flows outside the tube and its stroke is called the shell side.



The company has a first-class technical R & D team and more than 20 years of experience in manufacturing, air conditioner assembly and installation, and continuous innovation to satisfy customers.


Four return condenser maintenance

a. Ensure that the cooling tower, water supply system, water pump, and valve switches are normal and effective, and resolve any abnormalities in a timely manner.

b. Soften the cooling water quality, and often check the water quality and replace it.



How to distinguish it is a four-pass condenser

Answer: There are four or two split-range partitions welded in the end cover tube box of the four-pass condenser.


http://www.heatexchangermaker.com/